Skip to main content

ADPRO Troubleshooting

This guide covers common issues encountered when configuring and operating ADPRO devices with GCXONE, along with step-by-step solutions.

🔧

Troubleshooting

Quick Solutions

Alarm Transmission Issues

No Alarm Transmission

Symptoms

  • Alarms not appearing in GCXONE
  • No communication between ADPRO and GCXONE
  • Site pulse not working

Solutions

  1. Verify Unique Server ID
    • Ensure each device has a unique Server Unit ID
    • Check that the same ID is not used on multiple devices
    • Server IDs must be unique across all ADPRO devices
    ADPRO General Settings - Server Unit ID
  2. Check IP Addresses
    • Verify primary receiver IP address provided by NXG support team
    • Confirm secondary receiver IP address if configured
    • Test network connectivity to receiver IPs
    ADPRO Primary Alarm Transmission
    ADPRO Secondary Alarm Transmission
  3. Verify Network Connectivity
    • Test connection to virtual receiver
    • Check firewall rules allow traffic to receiver
    • Verify VPN connection if using VPN
    • Confirm whitelisting is configured correctly
    ADPRO CMS Alarm Transmission
  4. Test Transmission Paths
    • Test both primary and secondary transmission paths
    • Verify site pulse/lifecheck is configured
    • Check alarm profiles are properly configured
    ADPRO Site Pulse Configuration

Analytics Issues

Analytics False Alarms

Symptoms

  • Too many false alarms from analytics
  • Alarms triggered by non-threat objects
  • Missing actual security events

Solutions

  1. Adjust Sensitivity Levels
    • Reduce sensitivity for detection zones
    • Fine-tune size and speed criteria for moving objects
    • Test different sensitivity settings
    ADPRO Detection Parameters
  2. Refine Detection Zones
    • Review and modify detection zone boundaries
    • Exclude areas with frequent non-threat movement
    • Focus zones on critical entry points
  3. Configure Analytics Types
    • Use Intrusion Trace for entry point monitoring
    • Configure Loiter Trace for restricted areas
    • Set up Motion Sabotage for camera protection
    ADPRO Analytics Configuration

Scheduling Issues

Arm/Disarm Schedule Problems

Symptoms

  • System not arming/disarming at scheduled times
  • Incorrect time-based behavior
  • Schedule not saving properly

Solutions

  1. Verify Time Zone Configuration
    • Ensure time zone matches customer location
    • Check DST settings if applicable
    • Verify time zone is correctly set in ADPRO XO client
    ADPRO Time Zone Configuration
  2. Check NTP Synchronization
    • Confirm NTP server is reachable
    • Verify NTP synchronization is working
    • Check device time matches GCXONE time
  3. Review Schedule Settings
    • Verify arm/disarm schedule is properly configured
    • Check schedule times are correct
    • Ensure schedule is saved and active
    ADPRO Arm/Disarm Schedule

User Access Problems

User Access Issues

Symptoms

  • NXG user cannot access device
  • Insufficient permissions for operations
  • User credentials not working

Solutions

  1. Verify User Rights
    • Check NXG user has appropriate rights (Administrative preferred)
    • Verify User rights if Administrative is not possible
    • Confirm user account is active
    ADPRO Users Configuration
  2. Check User Credentials
    • Verify username and password are correct
    • Test credentials in ADPRO XO client
    • Reset password if necessary
  3. Review Permissions
    • Ensure all required permissions are granted
    • Check camera-specific permissions if applicable
    • Verify permissions match GCXONE requirements

iFT Gateway Issues

iFT Gateway Configuration Problems

Symptoms

  • Event clips not recording
  • Custom properties not working
  • iFT Gateway not functioning properly

Solutions

  1. Verify Custom Properties
    • Check eventClipRecord is set to "True"
    • Verify eventClipRecordAlarmCode is set to "motion.perimeter"
    • Ensure custom properties are saved in GCXONE
    GC-X-ONE Custom Properties
  2. Check Device Subtype
    • Confirm device is actually iFT Gateway subtype
    • Verify device model supports iFT Gateway features
  3. Review GCXONE Configuration
    • Navigate to Device → Edit → Additional Settings → Custom Property
    • Verify all custom properties are correctly configured
    • Save changes and restart device if necessary

Quick Reference

✅ Common Fixes

  • Verify unique Server Unit ID
  • Check IP addresses from NXG support
  • Test network connectivity
  • Verify time zone and NTP
  • Check user permissions

❌ Common Mistakes

  • Using duplicate Server IDs
  • Incorrect IP addresses
  • Missing site pulse configuration
  • Wrong time zone settings
  • Insufficient user permissions

Need Help?